GDS International Nusajaya Johor Data Center Campus: 225MW+ Hyperscale & AI Hub

Status: Fully Operational / Active Multi-Building Expansion   |   Location: 1, Persiaran Teknologi Perintis, Taman Teknologi Johor, 79200 Iskandar Puteri, Johor Darul Ta'zim, Malaysia


Project Overview

GDS International’s Nusajaya Tech Park (NTP) Data Center Campus in Iskandar Puteri, Johor Bahru, is a flagship hyperscale digital infrastructure hub strategically positioned to serve Southeast Asia’s rapidly growing cloud, artificial intelligence, and enterprise markets. Delivering more than 225 MW of critical IT capacity across a 110,000 m² campus, the development is purpose-built to accommodate hyperscale cloud providers, global internet companies, content platforms, financial institutions, and high-performance AI/HPC computing environments requiring scalable, resilient infrastructure. Located immediately adjacent to Singapore, the campus benefits from cross-border dark fiber connectivity that enables ultra-low-latency access to Singapore’s financial district, cloud ecosystems, and regional internet exchanges while leveraging Malaysia’s greater availability of land, power, and long-term expansion opportunities. Designed for next-generation computing, the campus is engineered to support high-density rack deployments and incorporates liquid-cooling readiness to meet the thermal requirements of advanced GPU-based AI and machine learning workloads. As part of GDS International’s regional expansion strategy, the facility also integrates energy-efficient infrastructure and sustainable power initiatives to improve operational performance and environmental responsibility. Supported by carrier-neutral connectivity, resilient electrical and cooling systems, advanced physical security, and continuous infrastructure monitoring, the Nusajaya Tech Park campus serves as a critical gateway for digital transformation, cloud expansion, and AI infrastructure deployment across Southeast Asia.


Quick Facts

FieldValue
Project NameGDS International Nusajaya Johor Data Center Campus: 225MW+ Hyperscale & AI Hub
Location1, Persiaran Teknologi Perintis, Taman Teknologi Johor, 79200 Iskandar Puteri, Johor Darul Ta'zim, Malaysia
StatusFully Operational / Active Multi-Building Expansion
CommissioningPhase 1 (NTP1) Go-Live: Q3 2023 / Phased Buildout Across NTP Phase 1–3 (2024–2026+)
Total IT Load225+ MW Critical IT Power Capacity Allocation
Total Capacity225+ MW Total IT Capacity across a 110,000 m² (~1,184,000 sq ft) gross footprint across multiple data hall facilities
Tier LevelTier III Certified Architecture / ISO 27001, ISO 14001, SOC 2 Type II
Project TypePurpose-Built Greenfield Hyperscale, High-Density AI-Ready Colocation & Regional Cloud Gateway

City Profile

HeaderDetails
City NameJohor Bahru
Population~1.7 Million
Urban Agglomeration~2.5 Million (Iskandar Malaysia region)
City GDPRM 150 Billion (State of Johor)
Per Capita Income~RM 42,000
City TierTier 1 (Malaysia) / Global Secondary Hub
Key StrengthsProximity to Singapore, abundant land, favorable power costs

Companies Involved

HeaderDetails
Developer / Operator GDS Holdings Limited
Strategic Infrastructure Partner Tenaga Nasional Berhad (TNB) & Johor State Investment Entities
Construction Contractor Specialized Asian Mission-Critical EPC Contractors
MEP Engineering GDS International In-House Global Engineering & Technical Operations Teams
Network Connectivity Carrier-neutral platform featuring diverse subterranean fiber entrance vaults; redundant Meet-Me-Rooms (MMRs); direct low-latency cross-border optical dark fiber backhaul to Singapore carrier hotels, cloud zones, and regional subsea cable landing stations.
Power Infrastructure Dual 275kV high-voltage utility grid feeds supplied by Tenaga Nasional Berhad (TNB), static distributed 2N / N+1 uninterruptible power supply (UPS) system architecture, automated switchgear, and standby emergency diesel backup generator arrays with multi-day on-site fuel reserves.

Technical Specifications

HeaderDetails
Power Capacity225+ MW Secured Utility Power Allocation
UPS Redundancy2N / N+1 Distributed Redundant Static UPS Architecture
Cooling System High-efficiency chilled-water precision cooling plant with N+2 thermal redundancy, hot/cold aisle containment, Direct-to-Chip Liquid Cooling (DLC) readiness supporting 80+ kW GPU racks, and automated BMS environmental controls.
Connectivity Carrier-neutral access with direct low-latency cloud express on-ramps and cross-connect options across Southeast Asian and global networks.
PUE Target < 1.30 Annualized Operational Design PUE
Energy Mix Integrated with TNB high-reliability grid utility power with ongoing expansion into solar PPAs and green energy certificates in Johor.

Milestones

HeaderDetails
Announcement 2021
Construction Start 2022
Phase 1 Go-Live Operational (Q3 2023 – NTP1)
Full Buildout Active Multi-Building Campus Expansion

Investment Details

HeaderDetails
Total InvestmentEstimated $1,300,000,000+ USD Total Campus Capital Expenditure
Funding Corporate Capital Expenditure & Private Equity / Infrastructure Financing by GDS International