Solon AI Data Center Campus: Vantage OH-1 Specs

Status: Under Construction / Phase 1 Structural Build   |   Location: 70-Acre Campus, Solon, Cuyahoga County, Ohio 44139, United States


Project Overview

The Solon AI Data Center Campus (OH-1) is a $2 billion hyperscale infrastructure development by Vantage Data Centers in Solon, Ohio, near Cleveland, designed to support the rapidly growing requirements of artificial intelligence, cloud computing, and high-performance digital workloads. Spanning approximately 70 acres, the three-building campus is planned to deliver 96 MW of critical power capacity, providing the substantial electrical infrastructure required for high-density computing environments. The facility is tailored to accommodate advanced AI training workloads, cloud platforms, enterprise applications, and next-generation server deployments that require significantly greater computing and thermal capacity than conventional data center environments. A key feature of the campus is its ability to support liquid-cooled infrastructure, enabling efficient thermal management for densely packed computing equipment and high-performance processors. This capability is particularly important for AI and accelerated computing systems, where increased rack densities generate substantial heat and require advanced cooling technologies. The campus's location in Solon, within the broader Cleveland metropolitan area, provides access to established telecommunications infrastructure, regional business markets, and supporting utility networks. Its multi-building design also provides flexibility for phased deployment and future expansion as demand for AI and cloud infrastructure continues to increase. By combining substantial critical power capacity, hyperscale-ready facilities, liquid-cooling capabilities, and a strategically located site, the Solon AI Data Center Campus is positioned to serve hyperscalers, cloud service providers, enterprises, and technology companies with demanding computational requirements. The project reflects the broader industry shift toward larger, denser, and increasingly specialized data centers designed for AI and high-performance computing.


Quick Facts

FieldValue
Project NameSolon AI Data Center Campus: Vantage OH-1 Specs
Location70-Acre Campus, Solon, Cuyahoga County, Ohio 44139, United States
StatusUnder Construction / Phase 1 Structural Build
CommissioningH1 2026 Initial Delivery Target
Total IT Load~96.0 MW Total Planned Critical IT Capacity
Total Capacity~475,000 sq ft (~44,100 m²) total whitespace across 3 multi-story data center buildings
Tier LevelTier III Certified Infrastructure Standards
Project TypePurpose-Built Hyperscale AI Cloud & Enterprise Colocation Campus

City Profile

HeaderDetails
City NameSolon
Population23,679 (2025 estimate)
Urban Agglomeration~2.2 million — Cleveland metropolitan area
City GDPNot separately reported
Per Capita IncomeUS$69,798 (2020–2024)
City TierTier 2 – Affluent Suburban Business & Technology Hub
Key StrengthsStrong manufacturing and corporate base, high household income, skilled workforce, proximity to Cleveland, access to major highways, established industrial parks, and connectivity to Northeast Ohio's broader technology and infrastructure ecosystem.

Companies Involved

HeaderDetails
Developer / Operator Vantage Data Centers
Strategic Infrastructure Partner FirstEnergy / Illuminating Company, City of Solon, Silver Lake Partners
Construction Contractor Specialized Mission-Critical General Contractors & Engineering Partners
MEP Engineering Vantage Global Engineering & Mission-Critical Thermal Systems Teams
Network Connectivity Carrier-neutral facility with dual path-diverse subterranean fiber entrance vaults, dedicated Meet-Me-Rooms (MMRs), and direct access to regional fiber backbones.
Power Infrastructure On-site dedicated high-voltage utility substation connected to the FirstEnergy grid, static 2N / N+1 UPS modules, automated switchgear, and backup diesel generators.

Technical Specifications

HeaderDetails
Power Capacity~120 MVA Dedicated Substation Capacity
UPS RedundancyConcurrently Maintainable Tier III 2N / N+1 Static UPS Architecture
Cooling System Closed-loop air-cooled chillers with direct-to-chip liquid cooling capability, zero water consumption design, and cold-aisle containment.
Connectivity Low-latency dark fiber routes linking Solon directly to major Midwest fiber hubs in Chicago, Columbus, and Ashburn.
PUE Target < 1.20 Annualized Operational Design PUE
Energy Mix Regional grid power supported by Vantage's corporate commitment to achieve net-zero carbon operations.

Milestones

HeaderDetails
Announcement March 2024
Construction Start Mid 2024
Phase 1 Go-Live H1 2026
Full Buildout Multi-Phase Campus Delivery Through 2027

Investment Details

HeaderDetails
Total Investment~$2,000,000,000 USD (Estimated Total Campus Investment)
Funding Institutional Equity & Infrastructure Debt (Vantage Data Centers / DigitalBridge)