DataBank Virginia South Campus Culpeper: 192MW Sustainable AI Hub

Status: Under Construction / Active Phase 1 Development   |   Location: Technology Zone Industrial Park, Culpeper, Virginia 22701, United States


Project Overview

DataBank’s Virginia South Campus in Culpeper is a flagship hyperscale digital infrastructure development strategically positioned to extend Northern Virginia’s world-leading data center ecosystem beyond Ashburn’s "Data Center Alley." Developed across an 85-acre site within Culpeper’s designated Technology Zone, the multi-building campus is designed to deliver up to 192 MW of critical IT capacity, providing scalable infrastructure for global hyperscale cloud providers, artificial intelligence (AI), machine learning (ML), high-performance computing (HPC), enterprise platforms, and large digital service providers. Engineered for next-generation computing environments, the three-building campus supports high-density deployments exceeding 50 kW per rack, making it ideally suited for GPU-intensive AI training clusters and advanced cloud infrastructure. The facility incorporates highly efficient closed-loop cooling systems, resilient 2N electrical architecture, and an on-site utility substation to ensure reliable power delivery, operational resilience, and long-term scalability for mission-critical workloads. As a carrier-neutral campus, Virginia South features path-diverse underground fiber routes providing low-latency connectivity to Ashburn’s primary carrier hotels, cloud availability zones, internet exchanges, and international subsea cable gateways serving North America and global markets. Supported by advanced physical security, continuous infrastructure monitoring, and flexible colocation deployment options, the Virginia South Campus provides a future-ready platform for cloud expansion, AI innovation, enterprise digital transformation, and the continued growth of Virginia as the world's premier hyperscale data center region.


Quick Facts

FieldValue
Project NameDataBank Virginia South Campus Culpeper: 192MW Sustainable AI Hub
LocationTechnology Zone Industrial Park, Culpeper, Virginia 22701, United States
StatusUnder Construction / Active Phase 1 Development
CommissioningPhase 1 Go-Live: 2025–2026 / Multi-Phase Campus Buildout
Total IT Load192 MW Critical IT Power Capacity Allocation
Total Capacity192 MW Total Critical Power Capacity across 3 purpose-built facilities on an 85-acre footprint
Tier LevelTier III Certified Architecture / ISO 27001, SOC 1 Type II, SOC 2 Type II, PCI-DSS, HIPAA
Project TypePurpose-Built Greenfield Hyperscale, High-Density AI-Ready Colocation & Enterprise Cloud Hub

City Profile

HeaderDetails
City NameVirginia
Population≈ 1.77 million
Urban Agglomeration≈ 1.05 million (Charleston–Huntington–Parkersburg combined urban influence)
City GDP≈ USD 95–100 billion
Per Capita Income≈ USD 52,000
City TierTier-2 (Emerging / Strategic State Economy)
Key StrengthsStrategic East Coast proximity (close to DC, Virginia, Ohio, Pennsylvania)

Companies Involved

HeaderDetails
Developer / Operator DataBank
Strategic Infrastructure Partner Dominion Energy Virginia / Rappahannock Electric Cooperative (REC)
Construction Contractor Specialized US Mission-Critical EPC Contractors
MEP Engineering DataBank In-House Global Technical Infrastructure & Engineering Teams
Network Connectivity Carrier-neutral platform featuring subterranean path-diverse fiber entrance vaults; redundant Meet-Me-Rooms (MMRs); direct low-latency dark fiber backhaul linking to Ashburn carrier hotels (Equinix IAD ecosystem) and Virginia Beach subsea cable landing stations.
Power Infrastructure Dedicated 115kV/230kV high-voltage utility substation built on-site, static distributed 2N / N+1 uninterruptible power supply (UPS) modules, automated switchgear, and standby emergency diesel generator arrays with multi-day on-site fuel reserves.

Technical Specifications

HeaderDetails
Power Capacity192 MW Secured Utility Power Allocation
UPS Redundancy2N / N+1 Distributed Redundant Static UPS Architecture
Cooling System High-efficiency closed-loop air-cooled chiller plant requiring zero water consumption, Direct-to-Chip Liquid Cooling (DLC) readiness for ultra-high-density GPU arrays, and automated BMS environmental controls.
Connectivity Carrier-neutral host offering direct low-latency cloud express on-ramps and cross-connect options across North American fiber corridors.
PUE Target < 1.25 Annualized Operational Design PUE
Energy Mix High-reliability grid power integrated with options for 100% renewable energy sourcing and solar/wind Power Purchase Agreements (PPAs).

Milestones

HeaderDetails
Announcement 2023–2024
Construction Start 2024
Phase 1 Go-Live Target 2025–2026
Full Buildout Active Multi-Building Campus Expansion

Investment Details

HeaderDetails
Total InvestmentEstimated $1,500,000,000+ USD Total Campus Capital Expenditure
Funding Corporate Capital Expenditure & Private Equity Financing (DataBank / DigitalBridge)