Nscale Ward County Texas: 1.2GW Hyperscale AI Data Center & GPU Factory

Status: Under Development / Phased Operational Rollout   |   Location: Ward County, West Texas, USA


Project Overview

The Nscale Ward County Data Center is a large-scale hyperscale AI factory campus located in West Texas, developed in partnership with site owner Ionic Digital to support the next generation of artificial intelligence and high-performance computing workloads. The initial phase is designed to deliver approximately 240 MW of AI-optimized infrastructure capable of hosting around 104,000 NVIDIA GB300 GPUs, providing the compute capacity required for large-scale AI model training, fine-tuning, and real-time large language model (LLM) inference. The campus is engineered to meet the demands of hyperscale cloud providers and enterprise AI deployments, including a major anchor capacity agreement with Microsoft. To efficiently manage the thermal requirements of high-density GPU clusters, the facility incorporates advanced cooling technologies such as closed-loop direct liquid cooling (DLC) and rear-door heat exchanger (RDHx) systems, enabling reliable performance while improving energy efficiency. The development has been designed with long-term scalability in mind, with plans to expand the campus to approximately 1.2 GW of total capacity. In addition, Nscale has secured an option for a further 700 MW Phase 2 expansion, positioning the site as one of the largest planned AI infrastructure campuses in North America. With its advanced cooling architecture, significant power availability, and AI-focused design, the Ward County campus is expected to play a key role in supporting future hyperscale AI computing demand.


Quick Facts

FieldValue
Project NameNscale Ward County Texas: 1.2GW Hyperscale AI Data Center & GPU Factory
LocationWard County, West Texas, USA
StatusUnder Development / Phased Operational Rollout
CommissioningPhase 1 (240MW): Q3 2026 / Phase 2 Expansion: Late 2027+
Total IT Load240 MW (Initial Phase) / 1.2 GW (Full Buildout Target)
Total Capacity~1,200 MW (1.2 Gigawatts) Total Power Capacity
Tier LevelTier III / Tier IV Equivalent (Ultra-High-Density AI Specification)
Project TypeGreenfield Hyperscale AI Compute Factory & Supercluster Campus

City Profile

HeaderDetails
City NameTexas
Population~30.5 million (2025 est.)
Urban Agglomeration~27–28 million (major metro clusters combined)
City GDP~$2.4 trillion (2024 est., comparable to G7 economies)
Per Capita Income~$78,000
City TierTier 1 (Global Economic Powerhouse)
Key StrengthsEnergy (oil, gas, renewables), Data Centers & AI Infrastructure, Technology (Austin hub), Logistics & Trade (US–Mexico corridor), Manufacturing, Business-friendly policies, Large land & power availability

Companies Involved

HeaderDetails
Developer / Operator Nscale
Strategic Infrastructure Partner Ionic Digital (Site Leasing & Infrastructure Partner), Microsoft (Anchor Customer), NVIDIA (Technology Partner)
Construction Contractor Regional Industrial EPC & Modular AI Data Center Builders
MEP Engineering Advanced High-Density Liquid Cooling & Power System Engineering Specialists
Network Connectivity Ultra-low-latency carrier-neutral fiber paths linking directly to major US internet exchanges, fiber backbones, and cloud infrastructure corridors.
Power Infrastructure Direct utility interconnects leveraging ERCOT grid infrastructure, backed by high-capacity substation transformers, N+1/2N static UPS systems, and industrial backup generators.

Technical Specifications

HeaderDetails
Power Capacity240 MW Initial Phase / 1.2 GW Total Planned Campus Utility Load
UPS RedundancyN+1 / 2N High-Efficiency Static UPS with Battery Energy Storage Systems (BESS)
Cooling System Closed-loop Direct-to-Chip Liquid Cooling (DLC), Rear-Door Heat Exchangers (RDHx), and high-efficiency water-chilled loop systems.
Connectivity Redundant high-speed fiber routes supporting InfiniBand, RDMA, and high-throughput inter-rack interconnects.
PUE Target ~1.10 – 1.15 (Achieved through direct liquid cooling optimization)
Energy Mix High penetration of local West Texas solar, wind power, and grid-scale clean energy contracts.

Milestones

HeaderDetails
Announcement Q4 2025
Construction Start Late 2025 / Early 2026
Phase 1 Go-Live Q3 2026 (~240MW / 104,000 NVIDIA GB300 GPUs)
Full Buildout 2028–2029 (Targeting 1.2GW Total Operational Footprint)

Investment Details

HeaderDetails
Total InvestmentEstimated $3,500,000,000 USD to $5,000,000,000+ USD across full 1.2GW multi-phase deployment
Funding Nscale corporate capital, institutional infrastructure investment, and anchor hyperscale compute service contracts.